Out of propane, and now it won't relight

Ran the propane tank dry and now the fireplace won't come back? After a run-out, the gas piping has to be checked for leaks once the gas is turned back on, and pilots have to be relit following the unit's instructions.

Once your gas supplier has restored the supply and done its checks, our pros can relight and check the fireplace. Propane is heavier than air and settles low, so the unit's lighting instructions matter. Anything that won't relight gets diagnosed and priced. Talk to our gas fireplace specialists about relighting in Rochelle: (352) 675-6366.

Neither the Gulf nor Atlantic coast reaches Rochelle. Measured directly, about 10 miles separate Rochelle from the Gainesville reference point.

What's Included

Fixed on gas units in Rochelle

  • Logs reset to the maker's diagram
  • Gas conversions done with the maker's kit
  • Water-damaged controls replaced before use
  • Annual service for gas fireplaces in Rochelle

Local Conditions

Rooftop vent caps inland

Venting up through the roof leaves a gas fireplace in Rochelle with a termination cap exposed to sun, wind and falling leaves. A cap knocked crooked or clogged with debris can affect venting. Our pros check the cap from the roof or a ladder during a service and replace damaged parts from the vent maker's list. A clear, straight cap keeps the unit breathing.

How It Works

A gas repair visit in Rochelle

  1. Watch it and read the plate

    Our pros see the fault happen, then read the rating plate and pull up your unit's manual.

  2. Test from switch to valve

    Switch, receiver, sensors and ignition are tested in order, with readings recorded.

  3. Repair with listed parts

    The failed part is replaced with the maker's listed part, or the cause is cleaned and adjusted.

  4. Check the whole unit

    Checks appropriate to the model are completed and explained before any further work is proposed.

Why Choose Us

Specialists for pilots, ignition and valves

  • Locally owned and run
  • A family-run company
  • 100% satisfaction guarantee
  • Your inspection is free
  • Same-day visits available
  • Arrange a visit, take 10% off

Your unit's own manual guides the repair, from the troubleshooting chart to the log diagram.

  • Your price, upfrontYou see the fault and the price for your gas fireplace in Rochelle before any part is ordered.
  • Same-day service is availableSame-day repair visits are available when the schedule allows and the part is on hand.
  • Our workmanship warrantyNew parts keep the maker's warranty, and our workmanship warranty sits on the repair itself.

Meter-testing the pilot sensors

Two sensors sit in the pilot flame of a standing-pilot gas fireplace. The thermocouple produces a small voltage that holds the gas valve open for the pilot; the thermopile produces more, enough to power the valve for the main burner.

Maker troubleshooting charts, such as those in Hearth and Home's manuals, have the technician read each one in millivolts at the valve, with the pilot lit and with the switch closed.

Our pros take those readings before replacing anything. A weak reading points to a worn sensor or a pilot flame that isn't wrapping it; a good reading points elsewhere in the system.

Checking gas pressure at the valve

Every gas fireplace has two pressures listed on its rating plate: the inlet pressure coming into the valve and the manifold pressure going to the burner. The valve has test points where a gauge can read both.

Low inlet pressure starves the flame; the wrong manifold pressure makes it too big or too small. Our specialists read both with a gauge and compare them with the plate.

If the inlet pressure is off, the problem is upstream, in the supply or the regulator, and that's for your gas supplier or a gas contractor. If the manifold pressure is off, it's set at the valve, and the reading goes on your quote.

Relighting after a propane run-out

Once a propane tank runs dry, pilots go out and air can get into the lines. The fuel gas code has the piping leak-checked right after gas is turned back on, and that's the supplier's or a gas contractor's job before any appliance is relit.

Propane is heavier than air and settles near the floor, which is why maker lighting instructions tell you to smell at floor level around the unit before relighting.

Once the supply is restored and checked, our pros relight the fireplace to its instructions, confirm the pilot and burner, and diagnose anything that won't come back.

Free Inspection

Readings taken before any price

  • Inlet and manifold pressure against the rating plate
  • Where each log sits, and any logs that are cracked or broken
  • The safety barrier in front of the glass, and its condition
  • The rating plate, the model and which listed parts are still made

Claim 10% off your first service

Reserve today, and a first gas fireplace repair from our pros is 10% off.

FAQs

Gas unit trouble in Rochelle

Can you repair my gas fireplace in Rochelle?

We can. Our gas fireplace specialists work from your unit's manual on your free inspection in Rochelle. Having the make and model handy saves time on the visit.

Can you fix a fireplace that got wet?

Makers say not to use a unit if any part was under water. Our specialists replace every control part the water reached with the maker's parts before it runs again.

Get in Touch

Ask for a free look from our pros

Send a few details and we'll call you back to set up a visit.

  • Free inspection first
  • 100% satisfaction, guaranteed
  • No hidden fees, all upfront
Speak with a local pro(352) 675-6366

Leave your name and number, tell us what's going on, and we'll call you back to set up your free inspection.

Won't light? Call a gas fireplace pro

Discuss service for your gas fireplace in Rochelle, with your model's instructions guiding the work.

Get a Free Inspection

Call the Gainesville chimney experts

(352) 675-6366

Inspection at no charge, price in writing before any work

Call (352) 675-6366