
Local pros for chimney relining in Gainesville
Cracked or missing flue lining replaced with a liner sized to your appliance. Free inspection, local family business.
- Family owned and run
- Free inspection first
- 100% satisfaction, guaranteed
- Locally owned and operated
Request a Free Inspection
Got it, thank you
Thanks for reaching out. We'll be in touch soon to book your free inspection.
Prefer the phone? Call (352) 675-6366
What's Included
Chimney liner work for fireplaces and inserts
What do you burn, and in what? An open wood fireplace, a wood insert and an insert that runs on gas each need a different liner, sized differently. Our family-owned local specialists start there during a free inspection, look over the old flue, then fit a UL 1777 listed liner sized to your appliance's listing, insulated wherever the maker calls for it.
- Stainless steel chimney liner installation for wood fires
- Chimney flue liner installation matched to your appliance
- Insulated chimney liner where clearances require it
- Chimney liner replacement when the old one has failed
- Flue liner replacement after cracked tile turns up
- Top plate and cap fitted to finish the job
Photos
Liners, top plates and the flues they fit



How It Works
The day your new liner goes in
-
Clean and check the flue
The chimney and smoke chamber are swept, and loose or cracked masonry is repaired before a liner goes in.
-
Size it to the listing
The appliance's listing and the liner maker's tables set the diameter, and the pipe is kept round, since squashing it changes its area.
-
Wrap it and feed it down
Insulation goes on when clearances call for it, then the liner is lowered from the roof and connected at the bottom.
-
Top plate, cap, first fires
The liner hangs from a top plate, a cap goes on, and you get the maker's break-in steps for the first fires.
Your Options
Which liner your appliance needs
The appliance picks the liner, and our pros match one to yours.
Materials
Stainless, alloy and insulation for a new liner
- Standard stainless steel
- UL 1777 listed for burning wood, oil or gas, and the everyday pick for fireplaces and wood inserts.
- Higher-alloy stainless for gas
- A higher alloy some makers sell for high-efficiency gas units, since their exhaust is harder on metal.
- Aluminum liner
- For certain gas appliances only; one maker limits its aluminum liners to Category I gas and bars them from solid fuel.
- Insulation wrap
- Lets a liner reach zero clearance to wood where the maker allows it, and helps draft while cutting condensation.
- Hanging plate and rain cap
- The plate hangs the liner from the crown, and a cap on top shuts out rain, birds and debris.
Pricing Factors
What drives a relining price
Chimney height
Every extra foot of chimney adds liner, insulation and labor.
Diameter and alloy
Bigger diameters and acid-resistant alloys cost more than standard stainless.
Insulation
An insulated liner adds the wrap or poured insulation and the labor to put it in.
Prep before the liner
An offset flue, cracked tile to clear out or masonry repairs first all add to the job.
Claim 10% off your first service
Book a relining today, and our family-run pros take 10% off the first service they do for you.
Free Inspection
What we check before you reline the chimney
- Flue size, shape and any offsets or tight spots
- Flue tiles that have cracked, shifted or gone missing
- Your appliance's listing and outlet size
- Clearances to wood framing along the chimney
- The smoke chamber at the base of the flue
- The crown where the top plate will sit
- Liner, insulation and cap options, each with a price
Why Choose Us
Liners matched to what you burn
- Locally owned and run
- A family-run company
- 100% satisfaction guarantee
- Your inspection is free
- Same-day visits available
- Arrange a visit, take 10% off
Chimney liner installation starts with the appliance and the existing chimney. The permitted lining or venting system, its size and any insulation depend on that setup and the applicable instructions. Our pros explain the proposed scope and provide a written estimate before you decide on work. Talk through your appliance and chimney with our local business at (352) 675-6366.
- Your first service, 10% offBook your relining today and a 10% discount comes with your first service.
- Our workmanship warrantyOur workmanship warranty covers the install, alongside the liner maker's own terms.
- Free inspection firstA free inspection checks the old flue before any liner is recommended.
Local Conditions
Relining jobs across our five counties
In whichever of our five counties you live, a relining job starts the same way, with the closer inspection NFPA 211 calls for before a flue is relined.
Liner makers note that a permit may be required, and the building department that covers your address makes that call; the estimate shows who handles it when one is needed. Our pros book the install on a dry day, since the top plate and crown get sealed at the very end, and the maker's break-in steps are left with you.
FAQs
Ask about relining before you book
How long before a new liner can go in?
Standard stainless liners can be scheduled soon after you approve the price. Special alloys or insulated kits take longer to arrive, and the install itself fits in a day on a straightforward chimney.
Is the relining price written and free?
Yes. There's no charge for the inspection, and you'll get the liner, insulation, top plate and cap priced in writing so you can decide.
Do you install liners out in Hampton and Brooker?
Yes. Hampton and Brooker are Bradford County towns, and Bradford is one of the counties our pros serve, together with Union, Gilchrist, Levy and Alachua. Set up a free look at (352) 675-6366.
What happens on the day the liner goes in?
The chimney is swept, the liner is wrapped if it needs insulation and fed down from the roof, then connected at the bottom. A top plate and cap finish it off, and our pro explains the break-in fires.
Could my cracked flue tiles be patched so I skip relining?
Sometimes. A few cracks in otherwise sound tile can be repaired, and that's a flue repair job. When damage is widespread or the appliance is changing, a liner is the better fix. Ask for a free look and you'll see which.
Common Problems
When the old flue lining has given out
-
Chunks of clay tile in the firebox
The flue lining is breaking up. Our pros check how far it goes and reline if the tile can't be repaired.
-
A new insert that won't draw well
It's pulling through a flue that's too big or too cold. A liner sized to the insert fixes the draft.
-
Water stains with no rain behind them
Exhaust may be condensing in a flue that's too big. Relining with a liner listed for that appliance ends it.
-
An unlined brick chimney
Flue gases and heat are working straight on the brick. A listed liner gives the flue the lining the code expects.
-
Smoke seeping into an upstairs room
Gaps in the lining are letting it out. Stop using the fireplace until the flue has been inspected.
Get in Touch
Set up your free inspection
Send a few details and we'll call you back to set up a visit.
- Free inspection first
- 100% satisfaction, guaranteed
- No hidden fees, all upfront
Got it, thank you
Thanks for reaching out. We'll be in touch soon to book your free inspection.
Specialized Services
Repairing the flue you already have
Our Services
Other work inside the flue
Full service details
Why a flue needs a lining
The lining is what keeps heat and flue gases off the brick and away from the house framing. Section R1003.11 of Florida's residential code requires one in every masonry chimney, and it has to suit the appliance as that appliance's listing and instructions describe.
Lining options depend on the appliance, fuel and existing chimney. A listed system must be approved for that use, including its fittings and installation arrangement. Other accepted lining materials have their own requirements; material alone does not establish that a proposed liner is suitable.
The appliance picks the liner
For an open fireplace, flue sizing considers the fireplace opening and the chimney configuration. An insert has its own venting instructions, which may specify an approved liner and connection. Our pros use the requirements for the actual appliance instead of a ratio taken from another model.
For a gas appliance, use the venting permitted by its listing and installation instructions. The material, sizing and arrangement depend on that model and its exhaust conditions; a high-efficiency appliance does not automatically call for a metal liner. Existing venting needs assessment before an appliance is connected to it.
Insulated chimney liner, and when it's needed
When the clearance between the chimney and nearby wood can't be confirmed, liner makers call for an insulation wrap, and with it the system can reach zero clearance. A wrapped liner also runs warmer, so it draws better and condenses less, which counts most on a chimney running up an outside wall. Poured insulation is another option some systems allow.
Up on the roof on relining day
Before any relining, NFPA 211 wants a closer inspection, so our pros start with the flue swept and checked. Loose or cracked masonry gets repaired first. Tile that's still solid where it pokes above the crown may be left, and broken tile gets trimmed off.
The liner is fed down from the top and joined to the insert's collar or set into the smoke chamber. At the top, a plate fastened to the crown carries the weight, the insulation stops short of the crown so the liner can expand, and a cap goes on. Some makers ask for small, gentle fires for the first few hours, and those steps are left with you.
Ask which liner your appliance needs
We'll check the flue, fit a liner to your appliance and price it upfront, with the inspection free. Book it at (352) 675-6366.
Get a Free InspectionCall the Gainesville chimney experts
(352) 675-6366Inspection at no charge, price in writing before any work




